GB GB
1. Programming 'open door time'
English Page 45
G. Display functions and programming possibilities
• Press button 쒊 for more than 10 sec,
until LED 2 flashes quickly.
• Still hold programming button P and
press simultaneously button 팬 or 팫,
until LED 8 flashes quickly and all others
are on.
• Release button 쒊.
The control unit changes to programming
menu 'open door time'.
LED 1 flashes.
• With button 팬 or 팫 the 'open door
time' is set in steps from 1 (deactivated)
to 16 (255 sec.) (according to table).
• Save your setting with programming
button 쒊.
The control unit changes automatically to
the programming menu of 'warning time'.
Advice:
- Still hold programming button c, if after 2 sec. LED 2
starts to flash. To come to the programming of extended
operator functions, please hold programming button c
for further 8 sec. (LED 2 then flashes quickly).
- The menu 'open door time' is blocked if no photocell is
connected and activated.