Marantec Comfort 250 Betriebsanleitung Seite 82

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 88
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 81
English Page 82
K. Technical details
Garage door operator
Comfort 250, 252
Connected loads:
230 V
260 W (operation with lighting)
3,9 W (at standstill without lighting)
Door travel speed:
0,14 m/s with soft start and soft stop
Push and pull force:
Comfort 250: 700 N
Comfort 252: 1.000 N
Excess travel stop:
88 sec.
Lighting
1 x 40 W, E14,
Automatic closing timer:
with additional relay for signal light
connection,
available as accessory, and driveway
photocell
warning time adjustable
from 2 to 70 sec.
Open door time adjustable
from 5 - 255 sec.
Control voltage:
Low voltage below 24 V DC.
Automatic cut-out:
Electronic power limit through
microprocessor and voltage sensor.
Anti-block system:
Through microprocessor
and rpm sensor.
Device to prevent forced opening
of door:
Through microprocessor
and rpm-sensor.
Protection category:
Only for dry buildings.