H. Test instructions
Cause for error
• No voltage
• Thermal overload protection in
transformer is active.
• Control unit defective
• Static current circuit
(operating elements)
is interrupted.
• Photocell defective
• Photocell interrupted
• Electronic aerial not connected
or wrong installation.
• Wrong programming of hand
transmitter coding.
• Empty battery
• Door is too sluggish or is
blocked.
• Power limit is set too
sensitively.
• Photocell programmed but
not connected.
• rpm sensor defective.
• Door is too sluggish.
Error message
• Control light VOLTAGE
does not light up.
• Control light
MALFUNCTION is flashing /
error No. 36.
• Control light
MALFUNCTION is flashing /
error No. 6 or 15
• Control light IMPULSE
does not light up when
giving impulse by hand
transmitter.
• Control light
MALFUNCTION is flashing /
error No. 10 or 28
• Control light MALFUNCTION
is flashing / error No. 15.
• Control light
MALFUNCTION is flashing /
error No. 9.
Error
• Error
• No reaction on
impulse
• Photocell
• Remote control
• Power limit
- max. power
- learning power
• Door can only be
opened.
• Operator only starts
to run shortly.